<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-04 18-24-57
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.4 kHz 22 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 74 kHz 10051 17,3615
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,2 dBr 8,05 dBr 8,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 18:24, 4.01.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (58 dBuV) Max at: 74 kHz MIN: 10 kHz % above 75 kHz: 17,3615 Acquired: 2025/01/04 18:23:53 Total samples: 10051 Equivalent time: 0:08:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,6 dBr MIN: 7,2 dBr AVE: 8,05 dBr % above 10,0 dBr: 0,0 Last value: 8,2 dBr (2025/01/04 18:23:53) Station: 96.90 MHz, signal: 4/5 (58 dBuV) 18:17 18:18 18:19 18:20 18:21 18:22 18:23 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality